< img height="1" width="1" style="display:none" src="https://www.facebook.com/tr?id=381665473315624&ev=PageView&noscript=1" />

Double Flange Concentric Taper

Ductile Iron Pipe Fitting For DI Pipe

Types: Dismantling Joint, Universal Flange Adaptor, Universal Coupling, Ductile Iron Loose Flange Joint, DI Pipe Fitting, Saddle for PVC Pipe, Repair Clamp, Qucick Flange Adaptor, Gibault Joint, Restrained Flange Adaptor, Restrained Coupling, Valve, etc.    

Material: MATERIAL: Ductile iron grade 500-7/ 450-12 in accordance with ISO 1083 for ductile iron fitting body and retainer, EPDM/NBR for ring, steel zinced/dacro for stub.    


Introduction
 


Specification: DN50-DN2000(2"-80"), available with PN10, PN16, PN25 and PN40 flanges    

Ductile Iron Flange Fittings Standard: ISO2531, ISO4179, ISO8179, BS EN 545, BS EN598, BS4772, ISO7005-2, EN1092-2:1997, DIN2501, GBT13295    

Flange: PN10, PN16 or PN25 drilling in accordance with ISO 7005-2/EN 1092-2.    

Fluid Temperature: 0°C-50°C, excluding frost.    

Pipe ends: Spigot, socket or flanges.    

Internal coating: Cement mortar lining comply with ISO4179 or bitumen painting (Ave. min.70 micron) or Fusion Bonded Epoxy Coating    

External coating: Sprayed metallic zinc coating (min.150g/m²) according to ISO8179 + bitumen painting (min.70 micron) or epoxy powder coating or epoxy painting or according to customer’s requirements.    

Types: Dismantling Joint, Universal Flange Adaptor, Universal Coupling, Ductile Iron Loose Flange Joint, DI Pipe Fitting, Saddle for PVC Pipe, Repair Clamp, Qucick Flange Adaptor, Gibault Joint, Restrained Flange Adaptor, Restrained Coupling, Valve, etc.    

Material: MATERIAL: Ductile iron grade 500-7/ 450-12 in accordance with ISO 1083 for ductile iron fitting body and retainer, EPDM/NBR for ring, steel zinced/dacro for stub.    

Application: Municipal Use, Waterworks Pipelines, Piping Fittings, Water Engineering, Potable Water Use, Irrigation Use, Water Supply Project Use, Water Treatment Plants Use, Pumping Stations, Water Utility Sectors, Water-Supply Pressure Pipeline, Potable Water Pumping Station, Stormwater Lines, Fire Water Pumping Station, Fresh Water Pumping Station, ect.    

Test: In accordance with ISO 2531 / EN 545 / EN598 and 100% water pressure test.    


Dimensions of Double Flange Concentric Taper    

NdnLMass (kg)standard


PN10PN16PN25PN40
50401505.15.15.15.1ISO2531/EN545
60501306.16.166
65402006.76.76.66.6
65501706.96.96.86.8
65502006.76.76.66.6ISO2531/EN545
80322005.55.55.55.5
80402006.36.36.36.3
80501506.56.56.56.5
80501707.37.37.37.3
80502007.37.37.37.3
80601707.77.77.67.6
80602007.57.57.47.4ISO2531/EN545
80651507.57.57.47.4
80651708.18.188
80652007.97.97.87.8ISO2531/EN545
100501006.96.9


100501507.97.98.48.4
100501708.18.18.68.6
10050200999.59.5
100503009.49.49.99.9
100601708.48.48.88.8
100651708.88.89.29.2
100652009.49.49.89.8
100801508.88.89.39.3
100801709.29.29.79.7
100801959.39.39.89.8EN545-B
100802009.39.39.89.8ISO2531/EN545
1256020010.410.41112.2
12560400141414.615.8
1256520010.710.711.312.5
1258017010.510.511.112.4
1258020011.111.111.713
12580300131313.614.9
12510015010.910.911.512.8
12510017011.311.312.513.8
12510020011.311.312.513.8ISO2531/EN545
1505017010.810.811.813.9
1506020012.312.313.315.4
1506030014141517.2
1506520012.612.6


1506530014.314.3


1508015011.511.512.514.6
1508017011.911.912.915
1508020013131416.1
1508026013.913.914.917
1508040016.416.417.419.5
15010015012.512.51416.1
15010017012.712.714.216.3
15010020013.513.51517.1
15010022014.514.51618.1
15010030015.315.316.818.9
150125150131314.618
15012517013.913.915.518.8
150125200141415.618.9ISO2531/EN545
2008020016.516.318.423.7
2008027017.717.519.624.9
200803001918.820.926.2
2008060026.526.728.834.1
2001002001817.820.425.7
20010027018.618.42126.3
2001003002322.8


20010033020.320.122.728
20010060027.727.530.135.4
20012527020.119.922.629.2
2001253002221.8


20015020020.22023.130.5
2001502352120.823.931.3EN545-B
20015027021.821.624.732.1
2001503002221.824.632ISO2531/EN545
2508025023.723.327.237.3
25010020021.721.425.835.8
25010027023.723.427.837.8
25010030024.924.62939
25010060037.837.541.951.9
25012527025.124.829.340.7
2501502002625.730.742.9
25015027026.826.531.543.7
2501503002928.7


25015034529.829.534.546.7
25015060038.3384355
2502002002726.932.948.3
25020027030.329.835.851.2
2502003003029.535.551ISO2531/EN545
3008027028.628.333.949.4
3008060041.741.346.962.4
3001002002827.733.849.3
30010027029.529.535.651.1
3001502003029.736.353.9
30015027032.632.338.956.5
30015060046.34652.670.2
30020020033.53138.759.5
30020027036.135.543.264
30020030038.638


3002006005251.559.280
30025015034.83443.569
3002502003736.345.871.4
30025027040.74049.575.1
30025030042.241.55176.6ISO2531/EN545
35020027040.843.353.7

35020060058.460.971.3

35025027045.247.659.8

35025060064.66779.2

35030020045.448.562.4

35030027049.952.866.7

35030030051.954.868.7ISO2531/EN545
40020027046.951.264.6

40020030048.953.266.6

40020060066.77184.4

40025027051.255.470.6

40025030053.257.472.6

40025060072.87792.2

40030027056.360.577.4

40030030058.86379.9

40030060080.585101.9

40035027060.267.487

40035030062.769.989.5ISO2531/EN545
45020027054.662.475

45020060079.38799.6

45025027057.46579.4

45025060079.987.5102

45030060087.495111

45040027071.283.6105

45040030074.286.5108ISO2531/EN545
50010070094.6107.7119.4

500250700100.9114130

500300600103.5116.6134

500350600104.9121141

500400570114.8132.7155.7

500400600118.3136.2159.2ISO2531/EN545
50045030083104126

600400570140.2168.4194

600400600144.3172.5198

600450600143.4175200

600500570160.6194.7220.6

600500600164.7198.8224.7ISO2531/EN545
700400800204220


700600600202243ISO2531/EN545